Pete vree 331110 views. Single phase submersible pump control box wiring diagram 3 wire submersible pump wiring diagram in submersible pump control box we use a capacitor a resit able thermal overload and dpst switch double pole single throw.

6 7 2 And 3 Wire Control Circuits For Fluid Power Systems
3 wire control circuit. Pressure switch a in this. Basic wiring for motor control technical data. They can be used as a guide when wiring the controller. Figure 1 is a typical wiring diagram for a three phase magnetic motor starter. Basic control circuitsthree wire control circuits 1. Figure 3 right shows a more complex two wire control circuit that is used to control an air compressor.
This is a 3 wire control circuitdraw a circuit which is controlled by a handoffautohoa switch in the hand position a motor with overload protection which is connected to a fan will be controlled by a start button a stop button and a holding contactin the auto position the motor will be controlled by a temperature switch an increase in temperature. They show the relative location of the components. This circuit is still a two wire control circuit andits used to turn the air compressor on automatically when the pressure drops below 30 psi and to turn off the compressor when the pressure reaches 90 psi. Refer to the schematic shown in figure 184. The following is the simple schematic of a three wire 2 way switch wiring. How is it possible for a two wire control circuit to control the operation of a three phase motor.
Notice that the wiring diagram for the control and load circuit is shown in figure 3a and the ladder diagram of the control circuit is shown in figure 3b. Line diagrams show circuits of the operation of the controller. Ladder diagram basics 3 2 wire 3 wire motor control circuit duration. It means if the stop command is provided separately it is called 3 wire control and if separate stop command is not provided separately it is called as 2 wire control. What are the two major types of control circuits. The l2 terminals of both the switches are connected to one terminal of the light bulb while the other terminal of the light bulb is connected to neutral.
Line diagrams also called schematic or elementary diagrams show the circuits which form the basic operation of the controller. You can observe in the schematic that both the com terminals are connected together. These circuits are also. In both circuits shown above the reverse command can be ignored if not necessary for the application still the same circuit is applicable for 2 wire and 3 wire control. What type of switch is the thermostat. Here is the complete guide step by step.
The nec defines such circuits as that portion of the wiring system between the load side of the overcurrent protection device ocpd or the power limited supply and all connected equipment. Electric motors troubleshooting and understanding w tpc online webinar tpc. Control wiring 3 wire control start stop circuit the most common use of 3 wire control is a startstop control. The wiring connection of submersible pump control box is very simple. The l1 terminals of both the switches are connected to line or phase or live of the ac supply. The first way of wiring uses a couple of two way light switches with a 3 wire control.
They do not. These circuits are characterized by their usage and electrical power limitation which differentiates them from light and power circuits. Class 1 2 and 3 circuits are classified as remote control signaling and power limited circuits in the national electrical code nec. See image below for an example of 3 wire control being used to pull in a contactor to start a 3 phase motor. Figure 1 typical wiring diagram.